Ramsforge

LPG & Oil Boiler Installation RAMS for Off-Grid Jobs

No mains gas, no problem. Get a site-specific RAMS for LPG and oil boiler installs in minutes. No account needed, pay per document.

✓ Built around CDM 2015

What it covers on an off-grid install

  • Fuel leaks: gas connections pressure tested before commissioning, and oil lines and tank connections checked before and after.
  • Flue and CO: flue integrity, terminal clearances and combustion checked with a calibrated analyser.
  • The lift: two-person lift for the boiler and any tank sections, with mechanical aids where available.
  • Tank siting: fire separation distances from boundaries, openings and ignition sources, per the manufacturer and OFTEC/LPGA guidance.
  • Bunding: adequate bunding or spill containment confirmed before commissioning.

Built for off-grid patches

Oil and LPG heating is common in rural areas off the gas grid, from the Highlands and rural Wales to the South West and East Anglia. If your diary is full of farmhouses and village jobs, this one's for you.

Competence note: LPG is gas work, so it must be done by a Gas Safe registered engineer. Oil work is usually done by OFTEC-registered technicians. The RAMS doesn't replace either registration.

Applicable Regulations

Gas Safety (Installation and Use) Regulations 1998Oil Firing Technical Association (OFTEC) StandardsManual Handling Operations 1992

Hazard & Risk Assessment

Every hazard in the full document has a control measure and a risk rating before and after controls. Here is one example in full.

Sample hazard

Fuel Leaks (LPG/Oil)

Control: Pressure test all gas connections before commissioning, and check oil supply lines and tank connections for leaks before and after installation.

Initial Risk: HighResidual Risk: Low

Also covered in the full document:

  • Flue Gas & Carbon Monoxide Exposure
  • Manual Handling of Boiler & Fuel Tank
  • LPG/Oil Tank Siting & Fire Separation
  • Bunding & Spill Containment

Frequently Asked Questions

Does it cover both LPG and oil boilers?

Yes. It includes leak testing for either fuel, plus the flue and combustion checks both need.

Does it cover tank siting and bunding?

Yes. It covers fire separation distances for the tank and confirming bunding or spill containment before commissioning.

Do I need to be Gas Safe for oil?

No, Gas Safe covers gas, including LPG. For oil, OFTEC registration is the usual route. Either way, the RAMS sits alongside your registration, not in place of it.

In the full document

  • The control measure for each of the 5 hazards
  • Required PPE list for this job
  • A step-by-step method statement
  • Emergency procedures & contacts
  • A sign-off section, as a clean PDF — emailed to you and ready to download

How it works

  1. Pick your job.
  2. Add the site address.
  3. Preview your RAMS free.
  4. Pay £15 and the PDF lands in your inbox.

No account needed, pay per document. Every RAMS includes a method statement, 5 rated hazards with controls, a PPE list and emergency procedures, built around CDM 2015 and HSE guidance. Spotted something to change? Free corrections within 14 days.

Related jobs

Get this as a personalised, watermark-free PDF for your job.

Generate my RAMS — £15.00